Manufacturer
RGK
Brand Country
Russia Russia
Country of origin
China China
Warrantee period
12 months
Weight, kg
0.551
Length, mm
175
Width, mm
81
Height, mm
47
Battery Type
2 x AA
RGK DM-30 Digital Multimeter
Vendor code: 776448
Leave feedback
7 690 rub.
The price is set by the manufacturer.
Manufacturer RGK trades with VAT 20%
The price is valid for today, 04.06.2024.
+ 154 bonus rub. for purchase
Manufacturing time:
in stock
The total quantity of this product must be a multiple of the package size (1 pcs.)
The manufacturer has set a minimum order limit for this product
Add to cart
Delivery to the address:
Delivery to TC:
Pickup:
Payment:
by card or by account
Description

Description

RGK DM-30 digital multimeter is a universal and multifunctional device for solving problems of inspection, testing and diagnostics of electrical equipment. Rich features and compact size make this model an excellent solution for both home use and professional measurements in the field.

Technical features

  • Measurements in True RMS format.
  • Determination of the strength, polarity and frequency of current, resistance, voltage, temperature.
  • Checking diodes, LEDs, transistors, capacitors.
  • Display of MIN/MAX readings.
  • Fixing values on the screen with the HOLD button.
  • It is allowed to connect current tongs.
  • Auto-off after 15 minutes of inactivity.

Useful functions

In REL mode, the RGK DM-30 portable multimeter excludes a pre-fixed reference value from the result, which makes it possible to increase the accuracy of operation when checking small resistances and capacitors of small capacity. Also, relative measurements help to minimize the influence of electromagnetic noise and losses on test cables on the reliability of readings.

The NCV function turns the device into a voltage detector and helps to determine the presence of alternating voltage by non-contact method. It is most often used to check the zero and phase. If necessary, the multimeter can be switched to low-voltage mode to fix the signal <48 V.

Functions such as the fill factor calculation and the V.F.C. filter are used to diagnose pulse (PWM) equipment and circuits.

Temperature measurement

A thermocouple is included in the scope of delivery of the device, which allows you to measure the temperature up to 100 ° C. When connecting more advanced sensors of the "K" type, the limit of the recorded values increases to 400 ° C.

Safety

The RGK DM-30 professional multimeter complies with the CAT III 600V standard, so it can be used for diagnostics of switching equipment, switchboards and other elements of power grids. Built-in fuses, isolation of connectors and light and sound alarm, protect the device from overload and unexpected power surges.

Technical specifications:

DC voltage measurement Parameters
Measurement limits Resolution (unit of the lower category (E.M.R.)) Limits of the permissible basic absolute measurement error, mV, In
60.00 mV 0.01 mV ±(0.005*U+2 E.M.R.)
600.0 mV 0.1 mV
6,000 V 0.001 V ±(0.007*U+3 E.M.R.)
60.00 V 0.01 V
600.0 V 0.1 V
Note – U is the measured value of the DC voltage, mV, V
AC voltage measurement parameters
Measurement limits Frequency, Hz Resolution (unit of the lower category (E.M.R.)), Within the limits of the permissible basic absolute measurement error, mV, In
60.00 mV from 45 to 1000 0.01 mV ±(0.01*U+3 E.M.R.)
600.0 mV 0.1 mV
6,000 V 0.001 V ±(0.008*U+3 E.M.R.)
60.00 V 0.01 V
600.0 V 0.1 V
Note – U is the measured value of the AC voltage, mV, In
The parameters of measuring the electrical resistance to direct current
Measurement limits Resolution (low-order unit (E.M.R.)) Limits of permissible basic absolute measurement error, Ohms, ohms, MOm
600.0 ohms 0.1 ohms ±(0.01*R+2 E.M.R.)
6,000 kOhm 0.001 kOm
60.00 kOm 0.01 kOhm ±(0.008*R+2 E.M.R.)
600.0 kOhm 0.1 kOhm
6,000 MOM 0.001 MOm ±(0.012*R+3 E.M.R.)
60.00 MOm 0.01 MOm ±(0.015*R+5 E.M.R.)
Note – R is the measured value of the electrical resistance to direct current, ohms, kOhm, MOm
Electrical capacitance measurement parameters
Measurement limits Resolution (unit of the lower category (E.M.R.)) Limits of the permissible basic absolute measurement error, , nF, mcF, mF
9,999 nF 0.001 nF ±(0.04*C+10 E.M.R.)
99.99 nF 0.01 nF ±(0.04*C+5 E.M.R.)
999.9 nF 0.1 nF
9,999 UF 0.001 UF
99.99 UF 0.01 uf
999.9 UF 0.1 uf
9,999 mF 0.001 mF ±0,01*C
99.99 mF 0.01 mF
Note – C - measured value of electrical capacitance, nF, UF, mF
Frequency measurement parameters
Measurement limits Resolution (low-order unit (E.M.R.)) Limits of permissible basic absolute measurement error, Hz, kHz, MHz
99.99 Hz 0.01 Hz ±(0.001*F+4 E.M.R.)
999.9 Hz 0.1 Hz
9.999 kHz 0.001 kHz
99.99 kHz 0.01 kHz
999.9 kHz 0.1 kHz
9.999 MHz 0.001 MHz
Note – F is the measured frequency value, Hz, kHz, MHz
The lower limit of measurements is 9.999 Hz
Temperature measurement parameters using thermoelectric converters (thermocouples) according to GOST R 8.585-2001 (type K thermocouple)
Measurement limits, °C Resolution (low-level unit (E.M.R.)), °C Limits of permissible basic absolute measurement error, °C1
from -20 to 0 1 ±3 E.M.R.
S. 0 to +100 ±(0.01*T+3 E.M.R.)
sv. +100 to +400 ±(0.02*T+3 E.M.R.)
Note: T is the measured temperature value, °C
1 The infallibility is normalized without taking into account the error of the thermocouple used
AC power measurement Parameters
Measurement limits Frequency, Hz Resolution (unit of the lower category (E.M.R.)) Limits of the permissible basic absolute measurement error, mkA, mA, A
600.0 mkA from 45 to 1000 0.1 mkA ±(0.01*I+3 E.M.R.)
6000 µA 1 mkA
60.00 mA 0.01 mA
600.0 mA 0.1 mA
6,000 A 0.001 A ±(0.012*I+3 E.M.R.)
10.00 A 0.01 A
Note – I is the measured value of the AC power, mkA, mA, A
DC power Measurement Parameters
Measurement limits Resolution (unit of the lower category (E.M.R.)) Limits of the permissible basic absolute measurement error, mkA, mA, A
600.0 mkA 0.1 µA ±(0.007*I+2 E.M.R.)
6000 µA 1 mkA
60.00 mA 0.01 mA
600.0 mA 0.1 mA
6,000 A 0.001 A ±(0.01*I+3 E.M.R.)
10.00 A 0.01 A
Note – I is the measured value of the DC power, mkA, mA, and
the temperature coefficients
Modification Temperature coefficient/°C
RGK DM-30 0,1
Main technical characteristics
Name of the characteristic Meaning
Display bit depth 6000
Maximum voltage between the multimeter inputs and ground 600 V (true RMS value)
Overload indication OL
Input protection mkA/mA fuse FF 600 mA, 600 V, (Ø6x32 mm)
Input protection 10 A fuse F 10 A H, 600 V, (Ø6x25 mm)
Overload protection PTC thermistor, 600 V
Range selection automatic/manual
Normal measurement conditions:
- ambient temperature, °C
- relative humidity, %
from +18 to +28
from 30 to 80
Operating conditions of measurements:
- ambient temperature, °C
- relative humidity, %
from 0 to +40
75 at a temperature from 0 to +30 ° C
50 at a temperature of +30 to +40 °C
Storage temperature
Storage humidity
from -20°C to +50°C
to 80%
Working height above sea level up to 2000 m
Compliance with the measurement category CAT III 600 V
Electrical power supply parameters:
- DC voltage
3 In
Food 2 x 1.5V AA batteries
Overall dimensions (length x width x height) 175 x 81 x 47 mm
Weight (without batteries) 0.325 kg
Characteristics

Characteristics

General Specifications

Manufacturer
RGK
Vendor code
776448
Country of origin
China
Brand Country
Russia
Warrantee period
12 months
Production time
Available from the manufacturer
Minimum order
1

Dimensions of product

Length, mm
175
Height, mm
47
Width, mm
81

Specifications

Weight, kg
0.551
Battery Type
2 x AA
Measuring range
constant voltage: 60 mV - 600 V; alternating voltage: 60 mV - 600 V; constant current: 600 MA - 10A; alternating current: 600 MA - 10 A; resistance: 600 ohms - 60 mOhm; capacity: 9,999 nF - 99.99 mF
Operating temperature, °C
0 - +40

Additional characteristics

Barcode
4610011876448
Reviews (0)
Reviews (0)
Terms of delivery

Terms of delivery

Who provides the delivery of goods?

On the Enex marketplace, you order the product directly from its supplier, and Enex employees organize the delivery in the way you choose.

What are the delivery methods?

You can choose any convenient way for you to receive an order:
  • Pickup from partner locations or from the manufacturer's warehouse

    If the manufacturer or trading company has the possibility of pickup, you can pick up your goods yourself or use the services of any transport company. Pickup is free of charge.
  • Delivery to the terminal by a transport company

    Pick up the goods at the nearest terminal of the Business Lines shopping center or DHL in your city. The delivery time and cost depend on your region and the dimensions of the cargo - they will be known at the stage of ordering.
  • Delivery to the door by courier of the transport company

    Receive the goods at your address via a Business Lines courier or DHL. The delivery time and cost depend on the region and the dimensions of the cargo - they will be known at the stage of ordering.
You can find out the exact information about the delivery methods of your order when placing an order or by contacting us by phone 8 800 707-56-00 or email info@enex.market .

How can I keep track of the shipped product?

After you have selected your preferred delivery method and placed an order, you will be able to monitor the change in its status by the number in your personal account, and track the immediate location of the product by the track assigned by the delivery service. You will also receive email notifications about changes in the status of your order. This way, you will always know where your product is located and respond promptly to changes.

Payment methods

Payment methods

Payment by bank card online

You can pay for the goods with bank cards "Visa", "Master Card", "Mir", "JCB". Payment by bank card is made without commission.

To make a transaction, you will need:
  • your bank card number;
  • expiration date of your bank card;
  • CVV code for Visa / CVC code for Master Card: the last 3 digits on the signature strip on the back of the card;
  • confirm the card transaction, for example, with a one-time password from an SMS.

Payment according to the invoice

On the checkout page, select the “Invoice payment” option, and after placing the order, the system will automatically generate and send you an invoice for payment to the specified email address.

In order for the order to be accepted, the invoice must be paid within 3 days.

Payment with bonuses

The buyer can pay part of the order cost (up to 20%) with Enex bonuses. The procedure and conditions for calculating and debiting bonuses are specified in section 7 Rules of sale and delivery.

The seller's indication on the marketplace

Various suppliers of tools and equipment trade on the Enex marketplace. These can be both manufacturers and trading companies. In this case, the Marketplace acts as an agent (Chapter 52 of the Civil Code of the Russian Federation). Enex itself can also act as a seller for some products. Learn more about ordering from different suppliers.

Information about the supplier is always indicated when placing an order, as well as in the invoice (when paying by invoice) or in the receipt (when paying by card). The invoice contains the terms of delivery of the goods, which are accepted by the buyer when paying for it.

Read more about the rules of Sale and delivery
Return of the product

Return of goods

Is it possible to return the purchased product?

If you are not satisfied with the product purchased on the Enex platform, you can return it or exchange it under the conditions specified below. Since buyers conclude direct purchase and sale transactions with manufacturers on the Enex platform, the return of goods is carried out directly to manufacturers.

Rules for the sale of goods.

Return of goods of proper quality

For individuals

The buyer-an individual has the right to refuse the ordered goods at any time before receiving it, as well as after receiving the goods - within 7 days, not counting the day of purchase. The return of the goods is possible if its presentation and consumer properties are preserved, as well as a document confirming the fact and conditions of purchase of the goods.

The buyer does not have the right to refuse a product of proper quality having individually defined properties if the specified product can be used exclusively by the buyer acquiring it.

In case of refusal of the goods of proper quality, the cost of services for the organization of delivery to the buyer is not refunded. Transportation costs for the return of goods of proper quality are borne by the buyer. The method of returning the goods is determined by the buyer.

For legal entities

The return (exchange) of goods of proper quality by the buyer, who is a legal entity (individual entrepreneur), is not allowed, unless otherwise provided by the agreement with the supplier.

Return of goods of inadequate quality

For individuals

The buyer, who is an individual, in cases provided for by law, may return the goods of inadequate quality during the warranty period for the goods and demand a refund of the amount of money paid for the goods. The goods of inadequate quality, in agreement with the buyer, can be replaced with a similar product of proper quality.

For legal entities

The buyer, who is a legal entity (individual entrepreneur), in the event of the transfer of Goods of inadequate quality to him, has the right to make claims provided for in Article 475 of the Civil Code of the Russian Federation.

Distribution of responsibility

In case of return/replacement of low-quality goods, the cost of delivery of the goods is paid by the supplier. The supplier reserves the right to accept the goods of inadequate quality from the buyer and, if necessary, to check the quality of the goods. If, as a result of the examination of the goods, it is established that its shortcomings arose due to circumstances for which the supplier is not responsible, the buyer is obliged to reimburse the supplier for the costs of conducting the examination, as well as the costs associated with its storage and transportation of the goods.

If any defect is found in the product, the manufacturer and (or) the marketplace has the right to require the buyer to provide a photo of the product, the claimed defect, packaging, labeling (nameplate) of the manufacturer.

If the buyer, who is a legal entity (individual entrepreneur), refuses the goods of inadequate quality, such buyer is obliged to return such goods to the supplier. The buyer - an individual can also return the goods to the address of the supplier or Marketplace. 

Transportation costs for the return of low-quality goods are borne by the supplier or Marketplace.

The difference between the shades of the goods in the photo and the real goods is not a sign of poor quality.

For questions about the return or exchange of goods, please contact us by phone 8 800 707-56-00 or by email: info@enex.market .

Full list of refund and exchange conditions

RGK DM-30 Digital Multimeter
7 690 rub.
RGK DM-30 Digital Multimeter
RGK DM-30 Digital Multimeter
Leave feedback
Vendor code: 776448
7 690 rub.
+1 offer
from 6 990 rub.
RGK company was founded in 2006, and during this time we have earned a reputation as one of the market leaders in measuring construction equipment and geodetic tools.
Exhibitor page at the Enex exhibition
Already 220748 products from 690 manufacturers
Selling tools directly from the manufacturer
Comparison of prices of producers and trading companies
Direct dialogue with the manufacturer on commercial and technical issues