Tracing generator AG 120T
Description
The AG-120TM generator is designed for localization and diagnostics of underground utilities (cables, pipelines).
The maximum power of the generator is up to 300 watts (depending on the selected operating mode).
The device has no equal in terms of the qualitative ratio: power-resource-dimensions-weight.
Application of the AG-120TM generator
- To trace communications by electromagnetic method (cables, metal pipelines) and acoustic method (metal and NON-metallic pipelines).
- To carry out a highly efficient search for cable damage sites.
- To diagnose gas pipelines and identify damage to the insulation of protective coatings.
- Work with any receiver due to the possibility of selecting any operating frequency in the range of 200-10000 Hz.
Features of the AG-120TM generator
- Increased battery capacity compared to the AG-120T generator.
- Automatic matching for a given current in the load, instead of the output power, allows you to get the predicted signal level at the input of the search receiver.
- Multi-frequency (200...10000 Hz) the multifunctional device can be equipped with any search receiver using this frequency range.
- Automatic selection of output power by an "intelligent" power selection program.
- The built-in "output multimeter" shows the voltage, current, resistance and power in the load.
- High output current (up to 15 A) allows efficient operation on "low resistance" (up to short circuit) loads (for example, grounded pipelines).
- The high output voltage (220 V autonomous / 330 V with an additional battery) allows you to effectively trace "high-resistance" long-range communications.
- Multifunctional: work without direct connection with a resonant transmitting antenna, inductive clamps, a shock mechanism and an isolation monitoring sensor.
- The ability to work in rainy weather (on/off; viewing parameters with the lid closed).
Characteristics of the tracing generator AG-120TM
The frequency of the sinusoidal signal, Hz
- The frequencies f1, f2, f3 ("constant") 200...9999 Hz are selected in the range with a discreteness of 1 Hz and an accuracy of ± 0.05%, entered into non-volatile memory
- Frequency f1 ("temporary") 200...9999 Hz - is selected instead of one of the "permanent", is not stored in memory, exists until the power is turned off
Generation modes
Mode 1continuous "NP"
Mode 2short-term sending "PR" (intermittent):
- pulse duration - 100 ms;
- pulse repetition rate - 1 Hz
Mode 3dual frequency "2F" (simultaneous generation):
- the first frequency is 1024 Hz;
- The second frequency is 8192 Hz;
- the ratio of the amplitudes of the first and second frequencies is 4:1
Mode 4generation of shock pulses "UR" (shock mode):
- pulse amplitude is equal to the supply voltage, selected by automatic switching of power sources depending on the specified impact force ("C1", "C2" or "C3" in the "CURRENT" field)
- pulse repetition rate (beats), beats/min.:
- low - 30
- The average is 60
- high - 120
- pulse duration - minimally sufficient to produce an impact by the UM-112 mechanism, set automatically
Output parameters of sinusoidal generation
Output current, A
Maximum in manual mode:
- continuous and two-frequency generation 10
- short-term parcels 15
- Set for auto-negotiation - ten preset values in the range of 0.1...9.9 A, can be changed by the user with a discreteness of 0.1 A and stored in non-volatile memory
Maximum output voltage, V
- With an autonomous power supply of 220 (180 at "2F")
- With the addition of an external battery of 12 V 330 (260 at "2F")
- When powered by the mains supply unit 110 (90 at "2F")
Maximum output power, W
- When powered independently or from an external battery, 21 V 150 continuously at 1.3...300 ohms and "2F" at 1.3...200 ohms / 200 pulses at 0.8...200 ohms
- With the addition of an external battery 12V 200 continuously at 2.0...150 ohms and "2F" at 2.0...300 ohms / 300 pulses at 1.3...300 ohms
- From the power supply unit (SBP) 100 to 1.0...120 ohms continuously / pulses or 1.3...80 ohms at "2F"
note
With incomplete charging or (and) at frequencies above the "logarithmic middle" of the range (1.1 kHz), a decrease in maximum power is allowed with an increase in frequency and load resistance, but not more than 3 dB
The permissible load resistance
- is any (0...∞);
- current limitation on "low-resistance" loads, "Umax" on "high-resistance" loads
Load matching
- is automatic, ensuring that the set current in the load is reached;
- manual (using the "Up" or "Down" buttons)
Power supplies
- Built-in battery pack two lead-acid sealed 12 V/15 Ah batteries (AGM technology) with automatic switching of 12 V/30 Ah or 24 V/15 Ah
Power life at 0 ° C, depending on the power, not less than, h
Continuous and dual frequency generation
- 1,7 (at 150 W stand-alone / 200 W with additional acc. 12 V)
- 4.0 (at 65 W stand-alone / 100 W with additional acc. 12 V)
Pulse parcels of the same frequency
- 11 (at 200 W stand-alone/ 300 W with additional acc. 12 V)
- 25 (at 100 W stand-alone / 150 W with additional acc. 12 V)
Generation of shock pulses with a maximum frequency of 80 beats/min.
- 25 (with the force of impact "C2" autonomously or "C3" with additional acc.)
- 62 (with the force of impact "C1" is autonomous)
- Charging time of fully discharged autonomous batteries is no more than 8 hours
- Power supply unit for battery operation or charging output voltage 15 V, output current 15 A max
- Acceptable external batteries 11...14 V / 22...28 V
Functional features
Automatic functions
- selection of the optimal power supply mode (switching of internal and external power sources);
- auto-negotiation (reaching the set current in the load);
- automatic "intelligent" power output selection;
- a special program for controlling the transmitting antenna;
- Built-in automatic charger;
- automatic power off during idle (1 min.)
Automatic shutdown of generation (charging)
- when the batteries are discharged below the permissible limit;
- if the external voltage does not match the charging mode;
- if the permissible current consumption is exceeded;
- when the external power supply is turned off during the generation process;
- when the output is short-circuited during generation;
- if the generation mode does not match the presence/absence of an antenna at the output
Types of connected loads during the generation of "SIN"
- direct connection to the object with the "return" of current through the core or armor of the cable;
- direct connection to an object with a "return current through the ground" using a "grounding pin";
- inductive connection using a transmitting antenna at a frequency of 8192 Hz (selected automatically when connecting the antenna);
- inductive connection using transmitting "tongs" (cable selection from the bundle is possible)
Design parameters
- Pulse power output amplifier, CLASS D(BD), EFFICIENCY > 80%
Displayed parameters (LED ultra-bright digital indicators of a wide temperature range)
- all supply voltages;
- modes and settings;
- power supply;
- "OUTPUT MULTIMETER": "output voltage", "load current", "load resistance", "load power"
- Control nine-button keyboard and external power switch with an indicator of the presence of generation, ensuring operation in the rain with the lid closed (thanks to memorizing the set parameters), "Intuitive" interface
- Classification of electromagnetic compatibility according to GOST R 51318.22-2006 class A
- The permissible ambient temperature range during operation is -30...+45 °C.
- The degree of protection of the housing is IP54
- Overall dimensions of the electronic unit (case), not more than, mm 305x270x191
- The weight of the electronic unit, not more than 14.5 kg
Characteristics
General Specifications
Dimensions of packaged product
Dimensions of product
Specifications
Terms of delivery
Who provides the delivery of goods?
On the Enex marketplace, you order the product directly from its supplier, and Enex employees organize the delivery in the way you choose.What are the delivery methods?
You can choose any convenient way for you to receive an order:-
Pickup from partner locations or from the manufacturer's warehouse
If the manufacturer or trading company has the possibility of pickup, you can pick up your goods yourself or use the services of any transport company. Pickup is free of charge. -
Delivery to the terminal by a transport company
Pick up the goods at the nearest terminal of the Business Lines shopping center or DHL in your city. The delivery time and cost depend on your region and the dimensions of the cargo - they will be known at the stage of ordering. -
Delivery to the door by courier of the transport company
Receive the goods at your address via a Business Lines courier or DHL. The delivery time and cost depend on the region and the dimensions of the cargo - they will be known at the stage of ordering.
How can I keep track of the shipped product?
After you have selected your preferred delivery method and placed an order, you will be able to monitor the change in its status by the number in your personal account, and track the immediate location of the product by the track assigned by the delivery service. You will also receive email notifications about changes in the status of your order. This way, you will always know where your product is located and respond promptly to changes.Payment methods
Payment by bank card online
You can pay for the goods with bank cards "Visa", "Master Card", "Mir", "JCB". Payment by bank card is made without commission.- your bank card number;
- expiration date of your bank card;
- CVV code for Visa / CVC code for Master Card: the last 3 digits on the signature strip on the back of the card;
- confirm the card transaction, for example, with a one-time password from an SMS.
Payment according to the invoice
On the checkout page, select the “Invoice payment” option, and after placing the order, the system will automatically generate and send you an invoice for payment to the specified email address.Payment with bonuses
The buyer can pay part of the order cost (up to 20%) with Enex bonuses. The procedure and conditions for calculating and debiting bonuses are specified in section 7 Rules of sale and delivery.The seller's indication on the marketplace
Various suppliers of tools and equipment trade on the Enex marketplace. These can be both manufacturers and trading companies. In this case, the Marketplace acts as an agent (Chapter 52 of the Civil Code of the Russian Federation). Enex itself can also act as a seller for some products. Learn more about ordering from different suppliers.Return of goods
Is it possible to return the purchased product?
If you are not satisfied with the product purchased on the Enex platform, you can return it or exchange it under the conditions specified below. Since buyers conclude direct purchase and sale transactions with manufacturers on the Enex platform, the return of goods is carried out directly to manufacturers.
Return of goods of proper quality
For individuals
The buyer-an individual has the right to refuse the ordered goods at any time before receiving it, as well as after receiving the goods - within 7 days, not counting the day of purchase. The return of the goods is possible if its presentation and consumer properties are preserved, as well as a document confirming the fact and conditions of purchase of the goods.
The buyer does not have the right to refuse a product of proper quality having individually defined properties if the specified product can be used exclusively by the buyer acquiring it.
In case of refusal of the goods of proper quality, the cost of services for the organization of delivery to the buyer is not refunded. Transportation costs for the return of goods of proper quality are borne by the buyer. The method of returning the goods is determined by the buyer.
For legal entities
The return (exchange) of goods of proper quality by the buyer, who is a legal entity (individual entrepreneur), is not allowed, unless otherwise provided by the agreement with the supplier.
Return of goods of inadequate quality
For individuals
The buyer, who is an individual, in cases provided for by law, may return the goods of inadequate quality during the warranty period for the goods and demand a refund of the amount of money paid for the goods. The goods of inadequate quality, in agreement with the buyer, can be replaced with a similar product of proper quality.
For legal entities
The buyer, who is a legal entity (individual entrepreneur), in the event of the transfer of Goods of inadequate quality to him, has the right to make claims provided for in Article 475 of the Civil Code of the Russian Federation.
Distribution of responsibility
In case of return/replacement of low-quality goods, the cost of delivery of the goods is paid by the supplier. The supplier reserves the right to accept the goods of inadequate quality from the buyer and, if necessary, to check the quality of the goods. If, as a result of the examination of the goods, it is established that its shortcomings arose due to circumstances for which the supplier is not responsible, the buyer is obliged to reimburse the supplier for the costs of conducting the examination, as well as the costs associated with its storage and transportation of the goods.
If any defect is found in the product, the manufacturer and (or) the marketplace has the right to require the buyer to provide a photo of the product, the claimed defect, packaging, labeling (nameplate) of the manufacturer.
If the buyer, who is a legal entity (individual entrepreneur), refuses the goods of inadequate quality, such buyer is obliged to return such goods to the supplier. The buyer - an individual can also return the goods to the address of the supplier or Marketplace.
Transportation costs for the return of low-quality goods are borne by the supplier or Marketplace.
The difference between the shades of the goods in the photo and the real goods is not a sign of poor quality.