Diesel generators for data centers
It's no secret that one of the most important parameters for companies specializing in providing work with large amounts of information in the format of data centers is the continuous power supply of servers and computing equipment. Any, even short-term, disconnection of power supplies threatens not only damage to expensive equipment, but also much greater losses for business and private customers of data centers, since giant arrays of information pass through the data center servers, including, among other things, multimillion-dollar bank transactions, financial flows of small and large businesses and personal data individuals.
Taking into account all these introductory, as well as the rapidly progressing digitalization of the modern economy, it will not be difficult to imagine what damage even a short-term power outage at facilities of this kind can cause. Naturally, the information industry places increased requirements on the equipment used to provide emergency power supply in terms of reliability and reliability. Within the framework of projects to provide backup power supply to data centers, the TSS Group of Companies is ready to offer the client technical solutions that have repeatedly proven themselves on the positive side in real conditions.
Diesel generators for data centers based on MITSUBISHI engines
|
|
|
|
Diesel generator TMs 1540MC 1120 kW |
Diesel generator TMs 1650MC 1200 kW |
Diesel generator TMs 2200MC 1600 kW |
Diesel generator TMs 2750MC 2000 kW |
Mitsubishi has a history of 150 years and today the company is represented in such industries as energy, nuclear power, mechanical engineering, astronautics, shipbuilding, aircraft construction, chemical industry, automotive and many others. MHI is one of the recognized world leaders in the development and production of powerful diesel engines, designed, among other things, for use in generation. Engines of this brand serve as the basis for diesel power plants of the world's leading manufacturers and are operated at facilities where the maximum level of reliability of autonomous and backup power supply systems is required. The company invests heavily in the creation of new diesel engine technologies and the development of equipment with the highest possible level of reliability.
-
The DCP power corresponds to the rated power
-
An average load factor of 100 is allowed%
-
The average annual load factor of 100% and below is allowed
-
Annual operating time is not limited
-
110% overload is allowed for a maximum of 1 hour every 12 hours
-
Meets the requirements of Tier III and Tier IV
TSS Premium diesel power plants, mass-produced at the facilities of the TSS production complex in Ivanteevka near Moscow, designed on the basis of Mitsubishi engines, are presented in the power range from 1000 kW to 2000 kW. Depending on the customer's needs, diesel power plants can be additionally equipped with autorun, heating, fuel and oil pumping systems. Also, the Mitsubishi DES can be installed in a block container, which ensures the operability of the equipment in all weather conditions, in the temperature range from -60C ° to +40C ° (Arctic version).
Comprehensive solutions for high-quality and guaranteed power supply of data centers (data centers)
|
|
|
|
OFFICE CENTER OF THE GOVERNMENT OF THE MOSCOW REGION
|
KAZAKHTELECOM
|
PRODUCTION OF MEDICINES "R-Pharm”
|
ROLT PRODUCTION HOLDING
|
2 x Backup DSU 1680 KW Engine S16 R-F1PTAW2
|
1x Backup DSU 1600 KW Engine S16R-PTAA2
|
DSU 1120 kW S12R-PTA2 engine + 400 V generator
|
1x Backup DSU 2000 kW + 10.5 kV generator
|
Diesel power plants of the TSS Premium line with Mitsubishi engines are characterized by high reliability and low cost of generated electricity, which makes them in demand by customers of equipment for data centers in need of trouble-free sources of energy supply for objects of various purposes. The technical solution implemented by the specialists of TSS Group of Companies will provide a multiple increase in the reliability of the backup power supply system of the data center, and will expand the range of power regulation of the generated electricity for the most complete adaptation to the needs of the data center.